# DC Facilities Engineer

**Company**: Nebius
**Location**: Independence, Missouri
**Work arrangement**: onsite
**Experience**: senior
**Job type**: full-time
**Category**: Facilities & Maintenance
**Industry**: Technology

**Apply**: https://job-boards.greenhouse.io/nebius/jobs/5042862101?utm_source=yubhub.co&utm_medium=jobs_feed&utm_campaign=apply
**Canonical**: https://yubhub.co/job/dc-facilities-engineer-425a13fc-0d3/

## Description

Nebius is leading a new era in cloud infrastructure for the global AI economy. We are building a full-stack AI cloud platform that supports developers and enterprises from data and model training through to production deployment, without the cost and complexity of building large in-house AI/ML infrastructure.

As a DC Facilities Engineer at Nebius, you will independently operate, maintain, troubleshoot, and take end-to-end ownership of critical power, critical cooling, liquid cooling, and DCIM/BMS infrastructure systems. You will participate in incident management and commissioning activities, and mentor Associate DC Facilities Engineers.

**Core Responsibilities**

- Monitor and contribute to the tracking of critical environment maintenance and repair for assigned service lines to Nebius SLAs; identify and escalate developing faults before they impact service uptime.

- Independently operate, monitor, and troubleshoot critical power distribution infrastructure including UPS systems, PDUs, RPPs, and in-rack busbar power systems.

- Manage and maintain critical cooling infrastructure including CRAHs, CRACs, CDUs, and RDHx; perform capacity checks and leakage inspections.

- Participate in incident management for infrastructure-impacting events; support root-cause analyses, document findings, and contribute to CAPA execution under the direction of the Senior DC Facilities Engineer.

- Operate and administer DCIM and BMS platforms; build and maintain dashboards, alerts, capacity reports, and infrastructure records.

- Support deployment and commissioning of GB-scale liquid-cooled rack infrastructure including direct liquid cooling (DLC) systems, manifolds, and CDU connections.

- Perform and own preventive maintenance tasks for all critical power and critical cooling systems; maintain accurate maintenance logs and compliance records.

- Participate in site reviews, design reviews, and commissioning activities; prepare and review technical reports to document findings and communicate results.

- Enforce Nebius critical power and critical cooling safety procedures; act as safety lead for engineering work orders on live infrastructure.

- Collaborate with facilities, network, and technician teams on infrastructure changes, capacity expansions, and major deployments.

- Support adherence to Nebius standards and policies through documentation review and active participation in commissioning and design activities.

- Contribute to vendor and contractor coordination by supporting scheduling, site access, and execution of work per Nebius expectations and safe-working practices.

- Actively mentor and train Associate DC Facilities Engineers; guide them through systems operation, safe working practices, and structured skill development toward independent operation.

**Expected Capabilities / Expectations**

- Working proficiency across all critical power systems: UPS, PDU, RPP, in-rack busbar, and generator interfacing.

- Hands-on experience with critical cooling systems: CRAH/CRAC, CDU, RDHx, and water-side infrastructure including leak detection.

- Competent DCIM/BMS administration: alert management, capacity modeling, and dashboard reporting.

- Developing knowledge of GB rack liquid cooling technology, DLC manifolds, and heat rejection infrastructure.

- U.S. Data Center Career Framework - Technical Career Framework

- Ability to participate in and support incident management activities including RCA and CAPA documentation.

- Strong documentation discipline: change records, maintenance logs, capacity data, and incident write-ups.

- Clear and confident communication with facilities, network, and vendor teams during changes and incidents.

**Core Physical Requirements**

- Ability to stand and remain on your feet for extended periods, typically four or more consecutive hours during active shift operations.

- Ability to safely lift, carry, and position equipment weighing up to 50 pounds unassisted, and heavier loads with appropriate team-lift protocols or mechanical aids.

- Comfortable working at heights including ascending and descending ladders, raised platform equipment, and elevated data center infrastructure.

- Ability to work in confined spaces such as under raised floors, within enclosed rack enclosures, and in cable management pathways.

- Comfortable working in environments with variable temperatures, including cold aisle containment zones and active cooling infrastructure.

- Manual dexterity sufficient to handle small form-factor components, precision cabling, and fine connector installations.

- Visual acuity sufficient to read equipment labels, small-form-factor interface indicators, and detailed wiring diagrams in variable lighting conditions.

- Ability to push or pull equipment carts, server sleds, and wheeled infrastructure weighing up to 500 pounds on level surfaces.

**On-Call Requirement**

- This role includes on-call participation to respond to after-hours critical power and critical cooling events, infrastructure alarms, and urgent maintenance requiring prompt engineering response.

**Benefits & Perks**

- Competitive compensation

- Career growth and learning opportunities

- Flexibility and ownership

- Collaborative and innovative culture

- Opportunity to work on impactful AI projects

- International environment and talented teams

For more fresh new jobs, check out [yubhub.co](https://yubhub.co/).

## Skills

### Required
- UPS
- PDU
- RPP
- DCIM
- BMS
- CRAH
- CRAC
- CDU
- RDHx
- liquid cooling

---

Source: [Apply at job-boards.greenhouse.io](https://job-boards.greenhouse.io/nebius/jobs/5042862101?utm_source=yubhub.co&utm_medium=jobs_feed&utm_campaign=apply)
